Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 21
Filtrar
1.
Artigo em Inglês | LILACS, BBO - Odontologia | ID: biblio-1155003

RESUMO

ABSTRACT Objective: To evaluate the pulp tissue of rat molars after pulpotomies with mineral trioxide aggregate (MTA), BiodentineTM (BDT) and calcium hydroxide (CH) mixed with sterile saline solution (24 hours, 72 hours, 7 days and 15 days), through correlating MPO activity with active neutrophils and MMP8 activity with tissue remodeling. Material and Methods: Thirty-eight Wistar rats were randomly distributed into groups (control, I (MTA gray), II (BDT), and III (CH)) and subdivided according to the study period of 24 hours, 72 hours, 7 days or 15 days after pulpotomy. MMP8 activity was assessed through fluorescence technique, and MPO activity was determined using the MPO assay. Results: A gradual decrease of MPO and MM8 activity occurred in the group MTA over the experimental periods (p<0.05). Groups BDT and CH exhibited an increase in the activity at 7 and 15 days (p<0.05). Conclusion: MTA demonstrated a decrease in the values of MPO e MMP8. BDT and CH showed high neutrophilic and collagenase activity over the experimental periods.


Assuntos
Animais , Ratos , Pulpotomia/métodos , Materiais Biocompatíveis , Peroxidase , Metaloproteinases da Matriz , Cimentos Dentários , Brasil , Interpretação Estatística de Dados , Ratos Wistar , Polpa Dentária , Microscopia de Fluorescência/métodos , Dente Molar
2.
J Appl Oral Sci ; 27: e20180030, 2019 May 20.
Artigo em Inglês | MEDLINE | ID: mdl-31116277

RESUMO

OBJECTIVES: To evaluate the effect of calcium hydroxide (CH) associated with two different vehicles as a capping material for pulp tissue in primary molars, compared with mineral trioxide aggregate (MTA). METHODOLOGY: Forty-five primary mandibular molars with dental caries were treated by conventional pulpotomy using one of the following materials: MTA only (MTA group), CH with saline (CH+saline group) and CH with polyethylene glycol (CH+PEG group) (15 teeth/group). Clinical and periapical radiographic examinations of the pulpotomized teeth were performed 3, 6, and 12 months after treatment. Data were tested by chi-squared analysis and a multiple comparison post-test. RESULTS: The MTA group showed both clinical and radiographic treatment success in 14/14 teeth (100%), at all follow-up appointments. By clinical evaluation, no teeth in the CH+saline and CH+PEG groups had signs of mobility, fistula, swelling or inflammation of the surrounding gingival tissue. However, in the CH+saline group, radiographic analysis detected internal resorption in up to 9/15 teeth (67%), and inter-radicular bone resorption and furcation radiolucency in up to 5/15 teeth (36%), from 3 to 12 months of follow-up. In the CH+PEG group, 2/11 teeth (18%) had internal resorption and 1/11 teeth (9%) presented bone resorption and furcation radiolucency at all follow-up appointments. CONCLUSION: CH with PEG performed better than CH with saline as capping material for pulpotomy of primary teeth. However, both combinations yielded clinical and radiographic results inferior to those of MTA alone.


Assuntos
Compostos de Alumínio/uso terapêutico , Compostos de Cálcio/uso terapêutico , Hidróxido de Cálcio/uso terapêutico , Óxidos/uso terapêutico , Agentes de Capeamento da Polpa Dentária e Pulpectomia/uso terapêutico , Pulpotomia/métodos , Silicatos/uso terapêutico , Dente Decíduo/cirurgia , Hidróxido de Cálcio/química , Criança , Pré-Escolar , Combinação de Medicamentos , Seguimentos , Humanos , Estudos Prospectivos , Agentes de Capeamento da Polpa Dentária e Pulpectomia/química , Radiografia Dentária , Solução Salina/química , Solução Salina/uso terapêutico , Fatores de Tempo , Dente Decíduo/diagnóstico por imagem , Resultado do Tratamento
3.
Braz. dent. sci ; 22(3): 344-348, 2019. tab
Artigo em Inglês | LILACS, BBO - Odontologia | ID: biblio-1008884

RESUMO

Objective: Evaluate and compare the antimicrobial efficacy of four different commercially available children's toothpastes on bacteria growth inhibition from oral microbiota of young children. Material and Method: The toothpastes tested contained: 1100 ppm sodium fluoride, xylitol and 750 ppm sodium fluoride, xylitol and 500 ppm sodium fluoride, and xylitol and triclosan. Twenty 18 to 36 month-old children were selected. Nonstimulated saliva samples were collected and inoculated on brain heart infusion (BHI) agar. Toothpaste dilutions were applied into the agar wells and incubated at 37 ºC for 24 hours in microaerophilic conditions. Saline and 0.12% chlorhexidine were used as controls. Antimicrobial activity was determined in duplicate by agar-well diffusion technique. Bacterial growth inhibition zones were recorded in mm. Statistical analysis was performed using ANOVA and Tukey's test (p < 0.05). Results: All toothpastes showed antimicrobial activity when compared to negative control (p < 0.05). Toothpaste containing triclosan presented the highest antimicrobial activity followed, in this order, by xylitol and 750 ppm sodium fluoride, chlorhexidine, 1100 ppm sodium fluoride, xylitol and 500 ppm sodium fluoride and saline. Conclusion: Toothpaste containing triclosan and xylitol presented excellent antimicrobial activity, and may be considered a good option for young children. (AU)


Objetivo: Avaliar e comparar a atividade antimicrobiana de 4 dentifrícios infantis, comercialmente disponíveis, com relação à inibição do crescimento da microbiota oral em crianças. Material e Métodos: Os dentifrícios testados continham: 1100 ppm de fluoreto de sódio - xilitol e 750 ppm de fluoreto de sódio - xilitol e 500 ppm de fluoreto de sódio - xilitol e triclosan. Vinte crianças de 18 a 36 meses participaram dessa pesquisa. Amostras de saliva não estimulada foram coletadas e inoculadas em ágar de infusão cérebro-coração (ICC). Dentifrícios diluídos foram aplicados sobre os poços contendo ICC e incubados a 37 ºC por 24 horas em condições microaerofílicas. Solução salina e clorexidina a 0,12% foram usadas como controles. A atividade antimicrobiana foi determinada em duplicata pela técnica de difusão nos poços de ágar. Os halos de inibição do crescimento bacteriano foram registrados em mm. A análise estatística foi realizada usando ANOVA e teste de Tukey (p < 0,05). Resultados: Todos os dentifrícios mostraram atividade antimicrobiana, quando comparados com os controles negativos. O dentifrício contendo triclosan mostrou a maior atividade antimicrobiana, seguido, nessa ordem por dentifrício contendo xilitol e 750 ppm de fluoreto de sódio, clorexidina, dentifrício contendo 1100 ppm de fluoreto de sódio, dentifrício contendo xilitol e 500 ppm de fluoreto de sódio e pela solução salina. Conclusão: O dentifrício contendo triclosan e xylitol apresentou excelente atividade antimicrobiana podendo ser considerado uma vantajosa opção para crianças, contribuindo para o controle das cáries dentárias e reduzindo a ingestão de fluoretos.(AU)


Assuntos
Humanos , Lactente , Pré-Escolar , Higiene Bucal , Odontopediatria , Dentifrícios
4.
J. appl. oral sci ; 27: e20180030, 2019. tab, graf
Artigo em Inglês | LILACS, BBO - Odontologia | ID: biblio-1002410

RESUMO

Abstract Objectives: To evaluate the effect of calcium hydroxide (CH) associated with two different vehicles as a capping material for pulp tissue in primary molars, compared with mineral trioxide aggregate (MTA). Methodology: Forty-five primary mandibular molars with dental caries were treated by conventional pulpotomy using one of the following materials: MTA only (MTA group), CH with saline (CH+saline group) and CH with polyethylene glycol (CH+PEG group) (15 teeth/group). Clinical and periapical radiographic examinations of the pulpotomized teeth were performed 3, 6, and 12 months after treatment. Data were tested by chi-squared analysis and a multiple comparison post-test. Results: The MTA group showed both clinical and radiographic treatment success in 14/14 teeth (100%), at all follow-up appointments. By clinical evaluation, no teeth in the CH+saline and CH+PEG groups had signs of mobility, fistula, swelling or inflammation of the surrounding gingival tissue. However, in the CH+saline group, radiographic analysis detected internal resorption in up to 9/15 teeth (67%), and inter-radicular bone resorption and furcation radiolucency in up to 5/15 teeth (36%), from 3 to 12 months of follow-up. In the CH+PEG group, 2/11 teeth (18%) had internal resorption and 1/11 teeth (9%) presented bone resorption and furcation radiolucency at all follow-up appointments. Conclusion: CH with PEG performed better than CH with saline as capping material for pulpotomy of primary teeth. However, both combinations yielded clinical and radiographic results inferior to those of MTA alone.


Assuntos
Humanos , Pré-Escolar , Criança , Óxidos/uso terapêutico , Pulpotomia/métodos , Dente Decíduo/cirurgia , Hidróxido de Cálcio/uso terapêutico , Silicatos/uso terapêutico , Compostos de Cálcio/uso terapêutico , Compostos de Alumínio/uso terapêutico , Agentes de Capeamento da Polpa Dentária e Pulpectomia/uso terapêutico , Fatores de Tempo , Dente Decíduo/diagnóstico por imagem , Hidróxido de Cálcio/química , Radiografia Dentária , Estudos Prospectivos , Seguimentos , Resultado do Tratamento , Combinação de Medicamentos , Agentes de Capeamento da Polpa Dentária e Pulpectomia/química , Solução Salina/uso terapêutico , Solução Salina/química
5.
Rev. odontol. UNESP (Online) ; 48: e20180132, 2019. tab, ilus
Artigo em Português | LILACS, BBO - Odontologia | ID: biblio-991494

RESUMO

Resumo Introdução Os cimentos resinosos são extensivamente utilizados na fixação de restaurações indiretas de cerâmica e cerômero, sendo classificados em duas categorias: os cimentos resinosos convencionais, que não apresentam uma adesão inerente à estrutura dental e requerem o uso de um sistema adesivo e os cimentos resinosos autoadesivos, que não requerem um tratamento adesivo prévio do substrato dentário. Objetivo Avaliar a resistência de união de dois cimentos resinosos, convencional e autoadesivo, quando utilizados na cimentação de restaurações cerâmicas e ceroméricas, trazendo elementos para propiciar melhor compreensão da interação adesiva em procedimentos de cimentação com as referidas categorias de cimentos resinosos. Material e método Dentes humanos (n=20), cedidos pelo banco de dentes da Universidade Federal de Alfenas (UNIFAL), foram preparados para que cilindros de cerâmica ou de cerômero fossem cimentados utilizando-se dois tipos de cimentos resinosos (autoadesivo e convencional). Após a cimentação, 20 palitos foram obtidos e submetidos ao teste de tração, avaliando-se a força necessária para a fratura. Os valores obtidos foram submetidos à análise estatística empregando-se a análise de variância (ANOVA) e o teste de Tukey. Resultado As forças mínimas e máximas necessárias ao rompimento do cimento convencional foram superiores às mesmas requeridas para o rompimento da união promovida pelo cimento autoadesivo, bem como as medianas e as médias aritméticas, independentemente do material restaurador empregado. O teste de Tukey demonstrou que as diferenças entre os cimentos empregados são estatisticamente significantes, independentemente do material restaurador. Conclusão Os resultados deste trabalho sugerem que o material utilizado para a confecção dos corpos de prova (cerâmica ou cerômero) não influenciou na resistência à tração, sendo que o cimento convencional apresentou valores superiores de resistência.


Abstract Introduction Resin cements are extensively used in the fixation of indirect restorations of ceramics and ceramics, divided into two categories: conventional resin cements, which do not present an inherent adhesion to the dental structure and require the use of an adhesive system, and the self-adhesive resin cements, which do not require a prior adhesive treatment of the dental substrate. Objective: To evaluate the microtensile bond strength of two resin-based cements, conventional and self-adhesive, according to required operating protocols, when luting ceramic and indirect composite restorations. Material and method Human molars (n=20) donated by UNIFAL teeth bank were prepared and, after being divided into two groups, ceramic or composite cylinders were luted to them with two resin-based cements (conventional and self-adhesive). Prepared teeth were sectioned vertically in both buccal-lingual and mesio-distal directions, to obtain 8 mm high, square-shaped "sticks" that were subject to microtensile bond strength test, and the necessary force to fracture them was evaluated. Results were subject to two-way ANOVA and Tukey test. Result Minimum and maximum forces to disrupt conventional cement were greater than the required one for self-adhesive cement, as well as mean bond strength, despíte of the restorative material. Tukey test showed that diferences were statistically significant, regardless the restorative material. Conclusion Restorative materials did not influence microtensile bond strength values, with no statistically significant differences. The difference between microtensile bond strength values of resin cements tested was statistically significant.


Assuntos
Resistência à Tração , Adesivos , Análise de Variância , Cimentos de Resina , Porcelana Dentária , Resistência ao Cisalhamento , Restauração Dentária Permanente
6.
RGO (Porto Alegre) ; 65(3): 196-201, July-Sept. 2017. tab
Artigo em Inglês | LILACS, BBO - Odontologia | ID: biblio-896019

RESUMO

ABSTRACT Objective: To evaluate the microhardness of specimens of acrylic resins VipiCril® (thermally polymerized resin) and Bosworth New Truliner® (self-polymerized resin), before and after immersion in solutions of 0.12% chlorhexidine digluconate, 1% sodium hypochlorite, Corega Tabs® and water (control), testing the null hypothesis that the mouthwashes and chemicals used to disinfect complete dentures do not interfere with the superficial microhardness, and can therefore be used as adjuncts to oral hygiene of edentulous patients. Methods: Sixty specimens of resin VipiCril®(thermally polymerized resin) and 60 specimens of resin Bosworth New Truliner® (self-polymerized resin) measuring 16 mm of diameter and 6 mm of height were prepared, which were randomly divided into four groups of 15 specimens each, undergoing Knoop hardness tests (KHN) both before and after cycles of immersion in solutions of 0.12% chlorhexidine digluconate, 1% sodium hypochlorite, Corega Tabs® and water (control). Results: The specimens of resins VipiCril and Bosworth immersed in solutions of 0.12% chlorhexidine, Corega Tabs® and water showed decreased microhardness. Conclusion: The 1% sodium hypochlorite solution caused least damage to the denture structure, not leading to decrease of the superficial microhardness.


RESUMO Objetivo: Avaliar a microdureza de corpos de prova das resinas acrílicas VipiCril® (resina termopolimerizável) e Bosworth New Truliner®(resina autopolimerizável), antes e após, a imersão em soluções de digluconato de clorexidine a 0,12 %, hipoclorito de sódio a 1%, Corega Tabs® e água (controle), testando a hipótese nula de que os enxaguatórios bucais e substâncias químicas utilizadas na desinfecção de próteses totais não interferem na microdureza superficial, podendo assim, serem utilizados como coadjuvantes na higiene bucal de pacientes desdentados. Métodos: Foram confeccionados 60 corpos de prova da resina VipiCril®(termopolimerizável) e 60 corpos de prova da resina Bosworth New Truliner® (autopolimerizável) com 16mm de diâmetro por 6mm de altura, estes foram divididos randomicamente em quatro grupos de 15 amostras cada, sendo submetidos a testes de microdureza Knoop (KHN), antes e após, ciclos de imersões em soluções de digluconato de clorexidine a 0,12%, hipoclorito de sódio a 1%, Corega Tabs® e água (controle). Resultados: Os corpos de prova de resina VipiCril e Bosworth imersos nas soluções de clorexidine a 0,12%, Corega Tabs®e água apresentaram diminuição de microdureza. Conclusão: A solução de hipoclorito de sódio a 1% causou menor dano à estrutura da prótese não causando diminuição da microdureza superficial.

7.
J Appl Oral Sci ; 24(2): 114-20, 2016 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-27119758

RESUMO

Because many mechanical variables are present in the oral cavity, the proper load transfer between the prosthesis and the bone is important for treatment planning and for the longevity of the implant-supported fixed partial denture. Objectives To verify the stress generated on the peri-implant area of cantilevered implant-supported fixed partial dentures and the potential effects of such variable. Material and Methods A U-shaped polyurethane model simulating the mandibular bone containing two implants (Ø 3.75 mm) was used. Six groups were formed according to the alloy's framework (CoCr or PdAg) and the point of load application (5 mm, 10 mm and 15 mm of cantilever arm). A 300 N load was applied in pre-determined reference points. The tension generated on the mesial, lingual, distal and buccal sides of the peri-implant regions was assessed using strain gauges. Results Two-way ANOVA and Tukey statistical tests were applied showing significant differences (p<0.05) between the groups. Pearson correlation test (p<0.05) was applied showing positive correlations between the increase of the cantilever arm and the deformation of the peri-implant area. Conclusions This report demonstrated the CoCr alloy shows larger compression values compared to the PdAg alloy for the same distances of cantilever. The point of load application influences the deformation on the peri-implant area, increasing in accordance with the increase of the lever arm.


Assuntos
Ligas Dentárias/química , Prótese Dentária Fixada por Implante/métodos , Análise do Estresse Dentário , Prótese Parcial Fixa , Análise de Variância , Ligas de Cromo/química , Força Compressiva , Planejamento de Prótese Dentária , Módulo de Elasticidade , Teste de Materiais , Paládio/química , Valores de Referência , Reprodutibilidade dos Testes , Prata/química , Estresse Mecânico , Torque
8.
J. appl. oral sci ; 24(2): 114-120, Mar.-Apr. 2016. tab, graf
Artigo em Inglês | LILACS | ID: lil-779907

RESUMO

ABSTRACT Because many mechanical variables are present in the oral cavity, the proper load transfer between the prosthesis and the bone is important for treatment planning and for the longevity of the implant-supported fixed partial denture. Objectives To verify the stress generated on the peri-implant area of cantilevered implant-supported fixed partial dentures and the potential effects of such variable. Material and Methods A U-shaped polyurethane model simulating the mandibular bone containing two implants (Ø 3.75 mm) was used. Six groups were formed according to the alloy’s framework (CoCr or PdAg) and the point of load application (5 mm, 10 mm and 15 mm of cantilever arm). A 300 N load was applied in pre-determined reference points. The tension generated on the mesial, lingual, distal and buccal sides of the peri-implant regions was assessed using strain gauges. Results Two-way ANOVA and Tukey statistical tests were applied showing significant differences (p<0.05) between the groups. Pearson correlation test (p<0.05) was applied showing positive correlations between the increase of the cantilever arm and the deformation of the peri-implant area. Conclusions This report demonstrated the CoCr alloy shows larger compression values compared to the PdAg alloy for the same distances of cantilever. The point of load application influences the deformation on the peri-implant area, increasing in accordance with the increase of the lever arm.


Assuntos
Ligas de Cromo/química , Prótese Dentária Fixada por Implante/métodos , Ligas Dentárias/química , Análise do Estresse Dentário , Paládio/química , Valores de Referência , Prata/química , Estresse Mecânico , Teste de Materiais , Reprodutibilidade dos Testes , Análise de Variância , Planejamento de Prótese Dentária , Força Compressiva , Torque , Prótese Parcial Fixa , Módulo de Elasticidade
9.
Full dent. sci ; 5(20): 548-554, jul.-set. 2014. ilus
Artigo em Português | LILACS, BBO - Odontologia | ID: lil-737442

RESUMO

A reabilitação da maxila edêntula com uso de implantes normalmente é limitada pela pouca quantidade óssea, devido ao padrão de reabsorção óssea na região anterior e pela presença dos seios maxilares na região posterior. Na tentativa da resolução dessas condições des¬favoráveis, algumas técnicas cirúrgicas têm sido propostas: enxertos ósseos, fixações zigomáticas, implantes curtos e implantes inclinados. Uma alternativa conservadora é o All-on-Four. Os implantes dentais inicialmente foram concebidos para serem colocados em uma posição vertical. Com o avanço das técnicas cirúrgicas, pacientes desdentados totais, extrações recentes, volume mínimo, pobre qualidade óssea e necessidade de enxertos tornaram-se situações desafiadoras para os profissionais. Para essas situações ficou demonstrado que o implante distai inclinado poderia ser vantajoso, já que preserva estruturas anatômicas importantes, permitindo a colocação de implantes mais longos, com boa ancoragem e em ótima posição para suporte protético. O tratamento de pacientes desdentados usando o conceito All-on-Four permite a instalação de uma prótese total fixada imediatamente aos implantes no mesmo ato cirúrgico. Para isto, quatro implantes são utilizados: dois orientados axialmente colocados na região anterior e dois implantes inclinados distalmente colocados na região posterior. Nos implantes da região anterior são colocados abutments retos e na região posterior os angulados, os quais servirão de suporte para uma prótese total provisória com carga imediata.


Edentulous maxilla rehabilitation with use of implants is usually limited by low bone amount, due to the pattern of bone resorption at the anterior region and the presence of the maxillary sinus at the posterior region. In an attempt to resolve these unfavorable condi¬tions, some surgical techniques have been proposed: bone grafts, zygomatic fixtures, short implants and tilted implants. A conservative alternative is the AII-on-Four. The dental implants were initially designed to be placed in a vertical position. With the advancement of surgical techniques, edentulous patients, recent extractions, minimum volume, poor bone quality, and grafts requirement have become challenging situations for professionals. For these situations it has been observed that the tilted distal implant could be advantageous, since it preserves important anatomical structures, allowing placement of longer implants, good anchorage and great position for prosthetic support. The treatment of edentulous patients using AII-on-Four allows the installation of a denture immediately fixed on the implants in the same surgical act.For this, four implants are used: two axially oriented placed at the anterior region and two tilted distal implants placed at the posterior region. In the implants of the anterior region right abutments will be placed and at the posterior region angulated ones will support a provisional denture with immediate loading.


Assuntos
Humanos , Implantes Dentários , Osseointegração , Planejamento de Dentadura/métodos , Procedimentos Cirúrgicos Bucais/reabilitação , Reabilitação Bucal , Estética Dentária , Radiografia Panorâmica/instrumentação
10.
Braz. dent. sci ; 16(2): 44-50, 2013. ilus, tab
Artigo em Inglês | LILACS, BBO - Odontologia | ID: lil-698289

RESUMO

Objective: This study aimed at evaluating the micro-hardness of an acrylic resin used for provisional crowns. Materials and methods: Five different processing techniques (direct and indirect) were assessed: (I) auto polymerizing resin in sandy stage; (II) auto polymerizing resin in plastic stage; (III) bead-brush technique; (IV) auto polymerizing resin under pressure; (V) heatcured acrylic resin under pressure. Five specimens were made for each test group. For the initial micro-hardness test, the specimens were immersed in deionized water for 48 hours. For the analysis of the final micro-hardness, the specimens were subjected to pH-cycling to simulate the changes in the pH level which occur in the oral cavity. Results: Tests revealed that the micro-hardness was decreased after the pH-cycling. However, no statistical difference was found among the different types of acrylic resin polymerization techniques. Conclusion: It was concluded that the micro-hardness is not directly related to the polymerization technique for making provisional


Objetivo: Avaliou-se a dureza superficial de uma resina acrílica (PMMA) utilizada para a confecção de coroas provisórias. Material e Métodos: Cinco diferentes técnicas de processamento (Direta e Indireta) para polimerização da resina foram testadas: I - autopolimerização após mistura (pó + líquido) em pote dappen e inserção em matriz de silicona na fase arenosa; II - autopolimerização após mistura em pote dappen com inserção em matriz de silicona na fase plástica; III - autopolimerização utilizando a técnica do pincel; IV - autopolimerização sob pressão em matriz de silicona; V - polimerização térmica utilizando líquido de polimerização rápida em mufla. Foram confeccionados cinco corpos-de-prova para cada grupo. Para o teste de microdureza inicial os espécimes foram imersos em água deionizada por 48 horas. Para a análise da dureza final, os espécimes foram submetidos a ciclos dinâmicos de pH, para simular a variação de pH ocorrida na cavidade oral. Resultados: Os testes revelaram que houve diminuição da dureza do material após a ciclagem ácida, porém não foi verificada diferença estatística entre os diferentes tipos de processamento da resina acrílica. Conclusão: Concluiu-se que a microdureza não está relacionada diretamente com a técnica de confecção dos provisórios.


Assuntos
Resinas Acrílicas , Coroas , Prótese Dentária , Prótese Parcial Temporária
11.
Full dent. sci ; 2(6): 166-170, 20110816.
Artigo em Português | LILACS, BBO - Odontologia | ID: biblio-850831

RESUMO

As coroas totalmente cerâmicas tem se tornado uma solução atrativa para fornecer reabilitação estética e funcional em dentes. O Sistema Procera® é atualmente um serviço restaurador dental que alia bom custo-benefício e alta qualidade. A proposta deste relato de caso foi ilustrar as vantagens deste sistema na reabilitação de dentes anteriores superiores. Uma paciente de 40 anos de idade se apresentou com a seguinte queixa: “desejo de melhorar a estética” dos incisivos centrais superiores com alteração de cor. Os dois incisivos centrais superiores foram preparados e coroas Procera® foram cimentadas. A qualidade do material e o potencial do sistema ajudou a resolver este caso restaurador com total confiança, tempo de trabalho reduzido e ótimo resultado estético


The all-ceramic crowns have become an attractive solution to provide functionaland esthetic rehabilitation on teeth. The Procera® system is currently providing cost-effective and high-quality dental restorative services. The purpose of this case report was to illustrate the advantages of this system for anterior rehabilitation. A 40-year-old patient presented with the chief complaint of “desire to improve esthetics” of discoloured upper central incisors. The two maxillary incisors were prepared and Procera Crowns were cemented. Material quality and the potential of this system helped resolve this restorative case with full confidence, reduced working-time, and optimum esthetic result


Assuntos
Humanos , Feminino , Adulto , Cerâmica , Coroa do Dente , Estética Dentária , Incisivo , Prótese Dentária , Restauração Dentária Permanente
12.
J Appl Oral Sci ; 19(3): 244-8, 2011.
Artigo em Inglês | MEDLINE | ID: mdl-21625741

RESUMO

OBJECTIVES: The complexity and heterogeneity of human bone, as well as ethical issues, frequently hinder the development of clinical trials. The purpose of this in vitro study was to determine the modulus of elasticity of a polyurethane isotropic experimental model via tension tests, comparing the results to those reported in the literature for mandibular bone, in order to validate the use of such a model in lieu of mandibular bone in biomechanical studies. MATERIAL AND METHODS: Forty-five polyurethane test specimens were divided into 3 groups of 15 specimens each, according to the ratio (A/B) of polyurethane reagents (PU-1: 1/0.5, PU-2: 1/1, PU-3: 1/1.5). RESULTS: Tension tests were performed in each experimental group and the modulus of elasticity values found were 192.98 MPa (SD=57.20) for PU-1, 347.90 MPa (SD=109.54) for PU-2 and 304.64 MPa (SD=25.48) for PU-3. CONCLUSION: The concentration of choice for building the experimental model was 1/1.


Assuntos
Implantes Dentários , Prótese Dentária Fixada por Implante/métodos , Módulo de Elasticidade , Poliuretanos/química , Análise de Variância , Fenômenos Biomecânicos , Humanos , Teste de Materiais , Modelos Teóricos , Resistência à Tração
13.
J. appl. oral sci ; 19(3): 244-248, May-June 2011. ilus, graf
Artigo em Inglês | LILACS | ID: lil-588130

RESUMO

OBJECTIVES: The complexity and heterogeneity of human bone, as well as ethical issues, frequently hinder the development of clinical trials. The purpose of this in vitro study was to determine the modulus of elasticity of a polyurethane isotropic experimental model via tension tests, comparing the results to those reported in the literature for mandibular bone, in order to validate the use of such a model in lieu of mandibular bone in biomechanical studies. MATERIAL AND METHODS: Forty-five polyurethane test specimens were divided into 3 groups of 15 specimens each, according to the ratio (A/B) of polyurethane reagents (PU-1: 1/0.5, PU-2: 1/1, PU-3: 1/1.5). RESULTS: Tension tests were performed in each experimental group and the modulus of elasticity values found were 192.98 MPa (SD=57.20) for PU-1, 347.90 MPa (SD=109.54) for PU-2 and 304.64 MPa (SD=25.48) for PU-3. CONCLUSION: The concentration of choice for building the experimental model was 1/1.


Assuntos
Humanos , Implantes Dentários , Prótese Dentária Fixada por Implante/métodos , Módulo de Elasticidade , Poliuretanos/química , Análise de Variância , Fenômenos Biomecânicos , Teste de Materiais , Modelos Teóricos , Resistência à Tração
14.
RPG rev. pos-grad ; 18(2): 108-112, abr.-jun. 2011. ilus, graf
Artigo em Inglês | LILACS | ID: lil-679849

RESUMO

This study aimed at evaluating the surface roughness and porosity of an acrylic resin used for provisional crowns. Six different processing techniques (direct and indirect) were assessed: (I) heat-cured acrylic resin under pressure; (II) heat-aided autopolymerizing resin under pressure; (III) autopolymerizing resin under pressure; (IV) bead-brush technique; (V) autopolymerizing resin in sandy stage; (VI) autopolymerizing resin in plastic stage. Twelve specimens were made for each test group. Roughness was evaluated with a rugosimeter, and porequantification was performed using a stereoscopic magnifying lens. The highest mean surface roughness (Ra = 0.908 mm) was measured for Group VI. The lowest surface roughness value (Ra = 0.141 mm) was determined for Group I. Significant differences in mean surface roughness were found between direct and indirect techniques. Direct techniques reached the highest roughness and porosity values; its use should be restricted to avoid creating favorable conditions for microorganism proliferation


Assuntos
Coroa do Dente , Prótese Dentária , Restauração Dentária Temporária , Odontologia , Ortodontia
15.
J Appl Oral Sci ; 19(1): 47-51, 2011.
Artigo em Inglês | MEDLINE | ID: mdl-21437469

RESUMO

OBJECTIVES: The complexity and heterogeneity of human bone, as well as ethical issues, most always hinder the performance of clinical trials. Thus, in vitro studies become an important source of information for the understanding of biomechanical events on implant-supported prostheses, although study results cannot be considered reliable unless validation studies are conducted. The purpose of this work was to validate an artificial experimental model based on its modulus of elasticity, to simulate the performance of human bone in vivo in biomechanical studies of implant-supported prostheses. MATERIAL AND METHODS: In this study, fast-curing polyurethane (F16 polyurethane, Axson) was used to build 40 specimens that were divided into five groups. The following reagent ratios (part A/part B) were used: Group A (0.5/1.0), Group B (0.8/1.0), Group C (1.0/1.0), Group D (1.2/1.0), and Group E (1.5/1.0). A universal testing machine (Kratos model K - 2000 MP) was used to measure modulus of elasticity values by compression. RESULTS: Mean modulus of elasticity values were: Group A - 389.72 MPa, Group B - 529.19 MPa, Group C - 571.11 MPa, Group D - 470.35 MPa, Group E - 437.36 MPa. CONCLUSION: The best mechanical characteristics and modulus of elasticity value comparable to that of human trabecular bone were obtained when A/B ratio was 1:1.


Assuntos
Implantes Dentários , Planejamento de Prótese Dentária/métodos , Prótese Dentária Fixada por Implante/métodos , Poliuretanos , Análise de Variância , Fenômenos Biomecânicos , Força Compressiva , Elasticidade , Teste de Materiais , Modelos Teóricos
16.
J. appl. oral sci ; 19(1): 47-51, Jan.-Feb. 2011. ilus, graf, tab
Artigo em Inglês | LILACS | ID: lil-578747

RESUMO

OBJECTIVES: The complexity and heterogeneity of human bone, as well as ethical issues, most always hinder the performance of clinical trials. Thus, in vitro studies become an important source of information for the understanding of biomechanical events on implant-supported prostheses, although study results cannot be considered reliable unless validation studies are conducted. The purpose of this work was to validate an artificial experimental model based on its modulus of elasticity, to simulate the performance of human bone in vivo in biomechanical studies of implant-supported prostheses. MATERIAL AND METHODS: In this study, fast-curing polyurethane (F16 polyurethane, Axson) was used to build 40 specimens that were divided into five groups. The following reagent ratios (part A/part B) were used: Group A (0.5/1.0), Group B (0.8/1.0), Group C (1.0/1.0), Group D (1.2/1.0), and Group E (1.5/1.0). A universal testing machine (Kratos model K - 2000 MP) was used to measure modulus of elasticity values by compression. RESULTS: Mean modulus of elasticity values were: Group A - 389.72 MPa, Group B - 529.19 MPa, Group C - 571.11 MPa, Group D - 470.35 MPa, Group E - 437.36 MPa. CONCLUSION: The best mechanical characteristics and modulus of elasticity value comparable to that of human trabecular bone were obtained when A/B ratio was 1:1.


Assuntos
Implantes Dentários , Planejamento de Prótese Dentária/métodos , Prótese Dentária Fixada por Implante/métodos , Poliuretanos , Análise de Variância , Fenômenos Biomecânicos , Força Compressiva , Elasticidade , Teste de Materiais , Modelos Teóricos
17.
Bauru; s.n; 2010. 159 p. ilus, tab, graf.
Tese em Português | LILACS, BBO - Odontologia | ID: lil-599159

RESUMO

O implante dental depende do osso de suporte para sua estabilidade e ongevidade funcional. O comportamento mecânico e a estrutura trabecular do osso afetam a interface com o implante. Tal conhecimento pode fornecer uma base para melhoramentos na função e desenho dos implantes atuais minimizando a reabsorção da crista óssea e falha na junção osso-implante. Desta forma a correta quantificação das forças que atuam sobre o sistema de implante e principalmente no osso de suporte ao qual ele está inserido é importante para o entendimento da biomecânica possibilitando que intervenções possam ser realizadas pelos profissionais visando assim à longevidade das próteses implanto-suportadas bem como dos implantes que as sustentam. Por essa razão, a proposta deste trabalho foi avaliar, com auxílio de extensômetros elétricos, se o processo laboratorial de confecção de coroas metalocerâmicas resulta em alterações das tensões no osso ao redor dos implantes. Para isto foi utilizado um modelo de poliuretano em forma de U simulando o osso mandibular com dois implantes de hexágono externo de 3,75mm de diâmetro por 13 mm de comprimento, nos quais foram fixados intermediários multi-unit. Os corpos de prova foram confeccionados com dois tipos de ligas odontológicas - Cobalto-Cromo e Paládio-Prata - e três tipos de cilindros protéticos calcinável, usinado de Cobalto-Cromo e usinado de Ouro. As leituras de deformação foram realizadas em dois momentos: 1- após a fundição das infra-estruturas e 2 após estas infra-estruturas terem recebido cobertura cerâmica. Os testes foram realizados parafusando os corpos de prova sobre os intermediários utilizando-se para isto um dispositivo eletrônico de torque com força máxima de 10 Ncm. Os resultados mostraram que, após a aplicação da cobertura cerâmica, ocorreu piora da condição de assentamento aos intermediários. O mesmo não foi detectado quando se avaliou a deformação do osso simulado, já que os valores de deformação não indicaram...


The dental implant depends on the supporting bone for its stability and functional longevity. Mechanical behavior and trabecular bone structure affect the interface with the implant. Such knowledge may provide a basis for improvements in the current implant function and design, decreasing bone crest resorption and failure at bone-implant junction. Adequate quantification of forces that act upon the implant system and mainly on the supporting bone is important for understanding the biomechanics, allowing the intervention by professionals with the purpose of achieving the longevity of implant-supported prostheses. Therefore, this work aims at evaluating, with the aid of strain gauges, whether the laboratorial process of metal ceramic crown fabrication results in changes of the tensions around the implants. A U-shaped polyurethane model simulating the mandibular bone with two 3.75-mm diameter and 13-mm length external hexagon implants were used with fixed multi-unit abutments. Specimens were prepared with two types of dental alloys - cobalt-chromium and silver-palladium - and three types of prosthetic cylinder castable plastic, prefabricated in cobalt-chromium or gold. The deformation readings were performed in two moments: 1- after framework casting and 2- after ceramic layering of the framework. The tests were performed with the framework screwed onto the abutments at 10Ncm using an electronic torque device. The results showed that the ceramic layering worsened the fit between the crowns and the abutments. The same was not detected when bone deformation was evaluated since the values were not statistically different.


Assuntos
Implantes Dentários , Prótese Dentária Fixada por Implante , Poliuretanos/química , Análise de Variância , Ligas de Cromo/química , Ajuste de Prótese
18.
Bauru; s.n; 2010. 159 p. ilus, tab, graf.
Tese em Português | LILACS, BBO - Odontologia | ID: biblio-865625

RESUMO

O implante dental depende do osso de suporte para sua estabilidade e ongevidade funcional. O comportamento mecânico e a estrutura trabecular do osso afetam a interface com o implante. Tal conhecimento pode fornecer uma base para melhoramentos na função e desenho dos implantes atuais minimizando a reabsorção da crista óssea e falha na junção osso-implante. Desta forma a correta quantificação das forças que atuam sobre o sistema de implante e principalmente no osso de suporte ao qual ele está inserido é importante para o entendimento da biomecânica possibilitando que intervenções possam ser realizadas pelos profissionais visando assim à longevidade das próteses implanto-suportadas bem como dos implantes que as sustentam. Por essa razão, a proposta deste trabalho foi avaliar, com auxílio de extensômetros elétricos, se o processo laboratorial de confecção de coroas metalocerâmicas resulta em alterações das tensões no osso ao redor dos implantes. Para isto foi utilizado um modelo de poliuretano em forma de U simulando o osso mandibular com dois implantes de hexágono externo de 3,75mm de diâmetro por 13 mm de comprimento, nos quais foram fixados intermediários multi-unit. Os corpos de prova foram confeccionados com dois tipos de ligas odontológicas - Cobalto-Cromo e Paládio-Prata - e três tipos de cilindros protéticos calcinável, usinado de Cobalto-Cromo e usinado de Ouro. As leituras de deformação foram realizadas em dois momentos: 1- após a fundição das infra-estruturas e 2 após estas infra-estruturas terem recebido cobertura cerâmica. Os testes foram realizados parafusando os corpos de prova sobre os intermediários utilizando-se para isto um dispositivo eletrônico de torque com força máxima de 10 Ncm. Os resultados mostraram que, após a aplicação da cobertura cerâmica, ocorreu piora da condição de assentamento aos intermediários. O mesmo não foi detectado quando se avaliou a deformação do osso simulado, já que os valores de deformação não ndicaram...


The dental implant depends on the supporting bone for its stability and functional longevity. Mechanical behavior and trabecular bone structure affect the interface with the implant. Such knowledge may provide a basis for improvements in the current implant function and design, decreasing bone crest resorption and failure at bone-implant junction. Adequate quantification of forces that act upon the implant system and mainly on the supporting bone is important for understanding the biomechanics, allowing the intervention by professionals with the purpose of achieving the longevity of implant-supported prostheses. Therefore, this work aims at evaluating, with the aid of strain gauges, whether the laboratorial process of metal ceramic crown fabrication results in changes of the tensions around the implants. A U-shaped polyurethane model simulating the mandibular bone with two 3.75-mm diameter and 13-mm length external hexagon implants were used with fixed multi-unit abutments. Specimens were prepared with two types of dental alloys - cobalt-chromium and silver-palladium - and three types of prosthetic cylinder castable plastic, prefabricated in cobalt-chromium or gold. The deformation readings were performed in two moments: 1- after framework casting and 2- after ceramic layering of the framework. The tests were performed with the framework screwed onto the abutments at 10Ncm using an electronic torque device. The results showed that the ceramic layering worsened the fit between the crowns and the abutments. The same was not detected when bone deformation was evaluated since the values were not statistically different.


Assuntos
Implantes Dentários , Prótese Dentária Fixada por Implante , Poliuretanos/química , Análise de Variância , Ligas de Cromo/química , Ajuste de Prótese
19.
Braz Oral Res ; 22(1): 43-7, 2008.
Artigo em Inglês | MEDLINE | ID: mdl-18425244

RESUMO

Cyanocrylates have been widely used in the medical and dental fields for several years. In Dentistry, cyanoacrylates have been used for suturing, pulp capping, as retrofilling material in endodontic surgeries, and as cervical plug for pulpless teeth bleaching. The biocompatibility of these adhesives has been the topic of many researches and subcutaneous implantation is an effective methodology for these studies. The present study evaluated the biocompatibility of three different cyanoacrylate-based adhesives. Thirty-six Wistar rats were used, divided into four groups of 9 animals each: A (control)--distilled water, B--cyanoacrylate ester (Super Bonder), C - n-butyl-cyanoacrylate (Histoacryl) and D--alpha-cyanoacrylate (Three Bond). The materials were dispensed in sponges of polyvinyl chloride, the animals were incised and the sponges were inserted in the subcutaneous tissue and sutured. Each group was sub-divided according to the time of sacrifice of the animals: 7, 21 and 45 days. Subjective analysis of the histologic material showed that all groups presented some degree of irritability, but the inflammatory reaction decreased with the experimental time in all groups. Group D showed an inflammatory reaction which was closer to that of the control group and was considered to have good biocompatibility. Groups B and C were similar and presented more aggressive inflammatory reactions when compared to the control group. Based on the results, it was concluded that alpha-cyanoacrylate (Three Bond) was the most biocompatible adhesive because it caused the lowest levels of inflammation.


Assuntos
Adesivos/efeitos adversos , Materiais Biocompatíveis/efeitos adversos , Cianoacrilatos/efeitos adversos , Retenção de Dentadura/normas , Materiais Restauradores do Canal Radicular/efeitos adversos , Tela Subcutânea , Animais , Materiais Biocompatíveis/normas , Avaliação Pré-Clínica de Medicamentos , Inflamação/etiologia , Inflamação/patologia , Próteses e Implantes/efeitos adversos , Ratos , Ratos Wistar , Obturação Retrógrada , Tela Subcutânea/patologia
20.
Braz. oral res ; 22(1): 43-47, Jan.-Mar. 2008. ilus, tab
Artigo em Inglês | LILACS | ID: lil-480582

RESUMO

Cyanocrylates have been widely used in the medical and dental fields for several years. In Dentistry, cyanoacrylates have been used for suturing, pulp capping, as retrofilling material in endodontic surgeries, and as cervical plug for pulpless teeth bleaching. The biocompatibility of these adhesives has been the topic of many researches and subcutaneous implantation is an effective methodology for these studies. The present study evaluated the biocompatibility of three different cyanoacrylate-based adhesives. Thirty-six Wistar rats were used, divided into four groups of 9 animals each: A (control) - distilled water, B - cyanoacrylate ester (Super Bonder), C - n-butyl-cyanoacrylate (Histoacryl) and D - alpha-cyanoacrylate (Three Bond). The materials were dispensed in sponges of polyvinyl chloride, the animals were incised and the sponges were inserted in the subcutaneous tissue and sutured. Each group was sub-divided according to the time of sacrifice of the animals: 7, 21 and 45 days. Subjective analysis of the histologic material showed that all groups presented some degree of irritability, but the inflammatory reaction decreased with the experimental time in all groups. Group D showed an inflammatory reaction which was closer to that of the control group and was considered to have good biocompatibility. Groups B and C were similar and presented more aggressive inflammatory reactions when compared to the control group. Based on the results, it was concluded that alpha-cyanoacrylate (Three Bond) was the most biocompatible adhesive because it caused the lowest levels of inflammation.


Assuntos
Animais , Ratos , Adesivos/efeitos adversos , Materiais Biocompatíveis/efeitos adversos , Cianoacrilatos/efeitos adversos , Retenção de Dentadura/normas , Materiais Restauradores do Canal Radicular/efeitos adversos , Tela Subcutânea , Materiais Biocompatíveis/normas , Avaliação Pré-Clínica de Medicamentos , Inflamação/etiologia , Inflamação/patologia , Próteses e Implantes/efeitos adversos , Ratos Wistar , Obturação Retrógrada , Tela Subcutânea/patologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...